Normal 410a pressures. Product Information FreonTM 410A is a non-ozone de...

The normal pressure for a typical R-401A mini-split ranges

During air conditioning mode, the pressure on the vapor line of an R-410A system will be somewhere between 102 to 145 PSIG. If the system had R-22, the vapor pressure would be between 58 to 85 PSIG but these pressures will be dependent on the wet bulb temperature inside the building and the ambient temperature outside the building.Aug 12, 2017 · r-410a pressure problem, 285/120 psig. i just installed a new split unit r-410a a/c system. it is running at 285/120 psig. the high side seems way low, should be about 420. the correct orifice is installed. this is a 1.5 ton condenser, 2 ton evaporator, and a 0.051 inch orifice. thanks for any suggestions. Forane 410A Pressure Temperature Chart Forane 410A, R-410A, Pressure Temperature Chart, PT Chart, HVAC, refrigeration, air conditioning, refrigerant gas I installed a new 410a complete system with new Orfice coil and new lineset. 70 degrees on install date and initial start up. Suction pressure was 110 and high side of 280. It ran for about 15 minutes. I added a little freon and the high side shot up to 425.May 16, 2017 · Cooling. In the cooling mode, running in outdoor temperatures below 55 degree without a "low ambient control' will cause symptoms very similar to low refrigerant. The cold outside air will cause the head pressure to drop which, in-turn, causes the suction pressure to drop. Try blocking part of the outdoor fan discharge to increase head pressure. While a blood pressure of 120/80 is normal for people over 18, for those under age 18, normal is based on a percentile rating for the teen’s age, height and gender, according to KidsHealth. A blood pressure above the 90th percentile is out ...The pressures were still at the 130 on suction side and 335 on the high side, but the cooling has gone away, suction side does not get cool. It has a metering orifice, no txv So, I thought I may be overcharged, since the liquid got in. I reclaimed some 410a (not measured) which sent the pressure too 150 on suction side and 365 on high side ...The typical 410a pressures on a 95 degree day are as follows; Liquid pressure: 296.4 psi Vapor pressure: 295.5 psi See all other pressures for R410 on different temperatures of the day from -49°F to 150°F below. R410a Pressure Chart High and Low Side R410 Temperature/pressure chart for low/high side psi: Pound per square inch, unit of pressureHypertension is characterized by high blood pressure, and it’s an important risk factor for heart disease. It’s a modifiable risk factor, which means you can make lifestyle changes to lower your blood pressure and improve your health.86°F. Any Tecumseh compressor with the letter “C” in the Model Number (Example: AWG5528CXD) is approved for use with R407C. shown in Figure 1. properties of R407C and R22. The data is taken at the standard refrigerant conditions of 5°F (-15°C) evaporating or 86°F (+30°C) condensing. Jul 16, 2021 · The liquid line pressure at 108°F saturation temperature is 356.5 PSIG. This screenshot of the Ref Tools app shows the liquid line pressure of R410A at saturation at 108°F. Notice how the slider has been set to BUBBLE point (inside the orange box). Vapor Line Pressure: Again, we already have the return air temp data, which is 74°F. Typical Low Side Pressure Range for R410A in the field: 115-120 psi. Typical High Side Pressure Range for R410A in the field: 410-420 psi. By 2025, high Global Warming Potential (GWP) refrigerants with a GWP of over 750, will be banned together with the systems using that gas. R410A has a GWP > 2,000.Physical Properties Of R22. In parallel to using the R22 PT chart, professionals will usually need to know some of the following R22 physical properties: R22 liquid density at -69°C: 1.49 g/cm 3. R22 gas density at 15°C: 3.66 kg/m 3. Triple point temperature: -115.76K. Critical pressure: 49.36 bar. Heat capacity ratio at 86°F: 1.178253.Freon™ 410A is intended for use in new air conditioning applications that have traditionally been serviced by HCFC-22. Many other applications are also possible, such as medium- and low-temperature refrigeration. Due to the significantly higher pressures that Freon™ 410A exhibits compared to HCFC-22, a typical compressor designedWe would like to show you a description here but the site won’t allow us. Refrigerant Pressure Temperature Chart - PT Chart for R-410A, R-134A, and R-22. These are currently the three most widely used refrigerants on the market today for HVAC applications in residential and commercial use. R-22 refrigerant is the king and used widely in the residential and commercial markets followed by R-134A which is used in ...R-410A 32/125 (50/50) A1 0.2 POLYOLESTER HFC blend; higher pressures, new equipment only. R-422B 125/134a/600a (55/42/3) A1 5 MINERAL OIL or ALKYLBENZENE, POE It can replace R22, R417A and R407C with existing oil in system High Ambient and Centrifugal Chillers R-124 100 A1 0 MINERAL OIL or ALKYLBENZENE Similar to R-114 - high ambient air ...What are normal operating pressures for 410A mini split? The low side pressure of a typical R410A mini split is between 110-140 psi depending on the operating conditions. However, it should not fall below 100 psi or raise beyond 160 psi. The working pressure of mini splits is depending on factors such as the weather and cooling load.The liquid line pressure at 108°F saturation temperature is 356.5 PSIG. This screenshot of the Ref Tools app shows the liquid line pressure of R410A at saturation at 108°F. Notice how the slider has been set to BUBBLE point (inside the orange box). Vapor Line Pressure: Again, we already have the return air temp data, which is 74°F.Jun 7, 2014 · Mini split manufacturers have been saying that since befrore R410A came out. All the old R22 units told you to weigh in charge only. And nobody is going to do that. It's like an quick change oil place telling customers that their engines have to be pulled and weighed to check their oil levels. No, its not the same. In this HVAC Training Video, I show the R-22 and R-410A Range of Operating Pressures on Air Conditioning Systems! I show why we Measure Pressures and Tempera... What are normal operating pressures for 410A mini split? The low side pressure of a typical R410A mini split is between 110-140 psi depending on the operating conditions. However, it should not fall below 100 psi or raise beyond 160 psi. The working pressure of mini splits is depending on factors such as the weather and cooling load.About this video in Learn Refrigerant 410A Gas complete information new technician must watch this video open this link https://youtu.be/O8TbwOxlo8kYou want ...Freon™ 407A are shown in Table 3. The pressure-enthalpy diagrams for Freon™ 407C are shown in Figures 1 and 2. Additional physical property data may be found in other Chemours publications. Thermodynamic properties booklets are also available for Freon™ 407C and Freon™ 407A in both English and metric units. Transport propertiesAn R-22 evaporator running at 40F saturation temperature will have a corresponding pressure of 68.5 psig. Should the suction pressure drop below 57 psig, the coil temperature will drop below 32F causing moisture in the air to freeze on it (see Figure 4) causing no end of trouble. A R-410A evaporator running below 100 psig will freeze-up just ...The typical 410a pressures on a 95 degree day are as follows; Liquid pressure: 296.4 psi Vapor pressure: 295.5 psi See all other pressures for R410 on …Measure the outdoor temperature in the shade entering the condenser. 3. ADD the CTOA (Condensing Temperature Over Ambient) based on the SEER rating, age or prior benchmarks. 4. Subtract the nameplate subcooling or 10 degrees if there is no nameplate. 5. Compare to the liquid line temperature.May 16, 2002 · OPERATING PRESSURE POINTS “Systems using R-410A operate at higher pressures [than R-22],” points out the Field Diagnostics team. “For example, to produce an evaporating temperature of 40 degrees F and a condensing temperature of 115 degrees, the suction and head pressures would be 83 psia and 257 psia in an R-22 system, while they would be 133 and 406 psia, respectively, in an R-410A ... The typical 410a pressures on a 95 degree day are as follows; Liquid pressure: 296.4 psi Vapor pressure: 295.5 psi See all other pressures for R410 on different temperatures of the day from -49°F to 150°F below. R410a Pressure Chart High and Low Side R410 Temperature/pressure chart for low/high side psi: Pound per square inch, unit of pressureGonzo, if your evap was dirty you would have a low suction and low superheat. Not dirty evap let that go. High suction low head, with 100 lb suc and 100 degree ambient your head should be quite a bit higher. Really need the amp draw of comp and rated RLA but appears to be a compressor issue.Typical low pressure or suction side pressure for R410A is about 120 psi,varying by ambient temperature,here assuming 75°F,may vary by equipment and …May 5, 2016 · The SC might be normal , but the normal head for a r410 system w/ a 68* ambient should be closer to 300psi and the normal suction press should be closer to 110psi w/70* IDB. Those p/t's sound more like r22. kdean1, buttwheat liked this post. As others have said it sounds like a TXV and maybe low on juice. The operating pressures with R-410A are higher than R-22. Typical head pressure will be somewhere in the 275 to 375 psi range, while suction will be in the vicinity of 150 psi. All R-410A systems use an expansion valve at the indoor coil. If one has a universal coil (one that can use R-22 or R-410A) the valve must be installed and the piston ...Buy PT Chart R22/R-410A Laminated Pocket Aid Pressure/Temperature # 34-3400-02: First Aid Kits - Amazon.com ✓ FREE DELIVERY possible on eligible purchases.The condenser comes charged with 15 feet of 410A. My install has 40 feet of 3/8" and 7/8" line total --- leaving 25 feet needing additional refrigerant. (Goodman suggest adding .6 oz per foot of liquid line) but that seems to be high. At the present time I am setting at 308 (High Side and 143 Low Side with no charge added beyond the 15 foot ...Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Created Date: 12/31/2018 2:21:34 PM ...About this video in Learn Refrigerant 410A Gas complete information new technician must watch this video open this link https://youtu.be/O8TbwOxlo8kYou want ...(○F) Liquid Vapor (○C). (○F) Liquid Vapor (○C). (○F) Liquid Vapor (○C). -49. 5.5. 5.4. -45.0. 1. 49.7. 49.5. -17.2. 51. 145.8 145.2. 10.6.Jan 14, 2020 · R22 gauge pressure is 10.9 bar or 158.2 psi. High side pressure typically varies by equipment and metering controls. Low pressure or suction side typically varies by equipment. Low-pressure refrigerant turns on the carrier HVACR at 50 psi (R22 pressure at 30 degrees) and closes at 100 psi (R22 pressure at 85 degrees). 22 sept 2017 ... Normal R410A Pressures = 100 to 150 psig Suction, 200 to 400 psig Head. Higher than Normal Head Pressure --> Step 2. Check High Pressure Issues ...The low side pressure will be lower than normal. This indicates the refrigerant absorbed too much heat while traveling through the evaporator. Over Charge- If refrigerant charge is high, the superheat will be low. The low side pressure will be higher than normal. This indicates the refrigerant did not absorb enough heat to properly change to a ...Apr 2, 2017 · Our Ebook, Paperback, Workbook, Quick Cards: https://www.acservicetech.com/the-book This video is on Normal Operating Pressures are for Freon R22 and R410A R... You can see that this R410A pressure chart includes high and low side pressures at temperatures ranging from -60 °F to 155 °F. Higher temperature equates to higher pressure. Here are 4 examplesof how you can use this chart: Example 1: What is the pressure of r410a at 72 degrees Fahrenheit? We can see that at … See moreThese units use R-410A refrigerant which operates at 50 to 70% higher pressures than R-22. Use only R-410A approved service equipment. Refrigerant cylinders are painted a “Rose” color to indicate the type of refrigerant and may contain a “dip” tube to allow for charging of liquid refrigerant into the sys-tem.HVAC R22, 410A Refrigerants! Checking the Charge- Vapor/Suction Operating Pressures, What is Too Low! P/T Chart on the Manifold Gauge Set is …The critical pressure and temperature of the R463A was found to be higher than the R404A, i.e. it can be used in a high ambient temperature environment, and emits a higher refrigerant effect and ...Post Likes. Head on 410 at 100° will be in the 375 - 400 range depending on surrounding conditions, sun, heat load inside, dirt on the coil. high suction pressure …What is the higher pressure of R-410A? Normally R-22 operating system typically have a high-side (discharge) pressure of 260 psig and low-side (suction) pressure of 76 psig, while a normally R-410A operating system have a high-side (discharge) pressure of 418 psig and low-side (suction) pressure of 130 psig at 45°F/7.2℃.equipment or components on R-410A equipment. Ensure service equipment is rated for R-410A.! WARNING Refrigeration systems contain refrigerant under pressure. Extreme caution should be observed when handling refrigerants. Wear safety glasses and gloves to prevent personal injury. During normal system operations, some components are hot and can ...™ 410A Refrigerant (R-410A) 0 0 20 40 60 80 Temperature (°F) 100 120 140 R-22 R-410A 100 200 300 400 500 600 700 Product Information Freon™ 410A is a non-ozone depleting high efficiency hydrofluorocarbon (HFC) refrigerant. Freon™ 410A has higher cooling capacity and operating pressures than R-22 for new equipment specifically designed ...Jan 9, 2017 · January 9, 2017. A restricted metering device — thermostatic expansion valve or TXV — can cause a number of symptoms in a system. Here are the ways a TXV can become restricted: Wax buildup in the valve because the wrong oil was used in the system; Sludge from the byproducts of a compressor burnout; Partial TXV orifice freeze-up from ... ™ 410A Refrigerant (R-410A) 0 0 20 40 60 80 Temperature (°F) 100 120 140 R-22 R-410A 100 200 300 400 500 600 700 Product Information Freon™ 410A is a non-ozone depleting high efficiency hydrofluorocarbon (HFC) refrigerant. Freon™ 410A has higher cooling capacity and operating pressures than R-22 for new equipment specifically designed ...The normal pressure for a typical R-401A mini-split ranges from 110-140 psi. However, keep in mind that the working pressure depends on factors like cooling load and weather. According to experts, the working pressure should never be less than 100 psi or more than 160 psi.What should the suction line temp be for a 410a system? Im measuring mine around 80F after the system runs for a bit (90-92F outside, 76-77F inside), which from what ive read is too hot. Unit is ground level and in the shade. ... AC blowing slightly cool (not cold) air even though the pressure in the system is within normal range.May 23, 2022 · Thread: Normal Static Pressures on 410A unit? Thread Tools. Show Printable Version; 05-23-2022, 07:47 PM #1. dooner90. View Profile View Forum Posts The low side pressure of a typical R410A mini split is between 110-140 psi depending on the operating conditions. Though it can vary, the low side pressure of a mini split should not fall below 100 psi or raise beyond 160 psi. The working pressure of mini splits is depending on factors such as the weather and cooling load.Jan 22, 2010 · With 75 indoor you should be running approximately 190 on the low side. The correct way to charge the unit would have been to weigh the charge in and in the cooling mode. So if you have 190 suction I would leave it as is and return when it is warm (70) outside to adjust the charge. Experience: 35 years in HVAC. These units use R-410A refrigerant which operates at 50 to 70% higher pressures than R-22. Use only R-410A approved service equipment. Refrigerant cylinders are painted a “Rose” color to indicate the type of refrigerant and may contain a “dip” tube to allow for charging of liquid refrigerant into the sys-tem.Our Ebook, Paperback, Workbook, Quick Cards: https://www.acservicetech.com/the-book This video is on Normal Operating Pressures are for Freon R22 and R410A R...Solstice® 454B (R-454B) is the most optimized R-410A replacement, providing easy conversion with minimal changes from a R-410A design. Thanks to its high critical temperature and broader operating envelope in low evaporating temperatures, Solstice® 454B outperforms other refrigerant alternatives in normal and410a low suction pressure. I injected super seal in a 410a system that had a tiny leak that I could not find. 2 years later I come across the problem of low suction pressure normal head pressure. Replaced txv and had same problem. Replaced compressor and had the same problem. Could the super seal be clogging the txv or …Cooling index merupakan tingkat pendinginan freon. Flammability merupakan tingkat kemudahan terbakar freonnya. Dari tabel tekanan freon R32, R22, dan R410a, bisa disimpulkan beberapa hal, yakni sebagai berikut. Freon R32 jauh lebih ramah lingkungan dibanding freon R410a karena tingkat GWP-nya lebih rendah dibandingkan freon R22 …Subcooling is a measurement of temperature DECREASE of a liquid below its saturation (mixed liquid/vapor) temperature at a given pressure. For example, water boils at 212° Fahrenheit at sea level …cylinder pressure requirement of 400 psig rating (DOT 4B400 or DOT 4BW400) ... Follow your typical sub-cooling or superheat procedures to arrive at the correct charge. Insta Charge . R-410A Gauges With Sight Glass Dedicated charge hoses Dedicated manifold R-410A hoses rated up to 550 to 800 PSIG . Manifold Gauge Set .Saturation Pressure-Temperature Data for R410A (psig)* *Red Italics Indicate Inches of Mercury Below Atmospheric Pressurehi, anyone familar with R410A. For air conditioning system, R22 pressure in discharge is250psi and suction in67psi. But for R410A pressure will be more higher that …A small amount of refrigerant will come out, which is normal; simply attach the hoses as quickly as possible to minimize the loss. Turn the R410 Tank valve to on. Flip the box of R410a upside down so the liquid will flow into the unit instead of vapor. With the mini split on and working, check the blue gauge pressure.(○F) Liquid Vapor (○C). (○F) Liquid Vapor (○C). (○F) Liquid Vapor (○C). -49. 5.5. 5.4. -45.0. 1. 49.7. 49.5. -17.2. 51. 145.8 145.2. 10.6.The vapor pressure is 118 PSIG and because it is 85°F outside, the R-410A bottle pressure is 254 PSIG. The pressure in the bottle is much higher than the pressure on the low side of the system so if they are connected, refrigerant will exit the bottle and enter the system. What are normal pressures for R-410A?What are normal pressures for 410A? A normally operating R-410A system with the same condensation temperature of 120 degrees and a 45 degree evaporator saturation temperature will have a high side pressure of 418 psig and a low side pressure of 130 psig.R410A PRESSURE-TEMPERATURE CHART Saturation Pressure-Temperature Data for R410A (psig)* ECLPC-1 Rev 1 – 02/22. Created Date: 2/25/2022 1:24:53 PM ...Online R454B pressure temperature chart spanning from -40°F to 150°F temp. Printable PDF version of R454B PT chart you can take with you on the job. There are several brand names for R454B: Opteon XL41, Solstice 454B, and Puron Advance. This is a blend of R32 (68.9%) and R1234yf (31.1%). It has a very low boiling point of -59.5°F (-50.9°C).What is the normal operating pressure for a 410A refrigerant? Suction pressure of an Air-Conditioner with R410A Refrigerants typically ranges between 115 Psig to 125 Psig when operated at an ambient temperature of 35 degC. The discharge pressure at this operating conditions hovers around 400 Psig. R-410A operates at pressures 50 …Normal saturated condensing temps, which vary with how clean the coil is, outdoor ambient temp, and indoor heat load, are higher than what you have here. Let's go with 20 degrees over ambient as a basic reference for this example: you should be seeing saturated condensing temps of 105°F, with a corresponding R410A pressure reading of 340 psig.pressures and refrigeration capacity than R-22. The compositions of Freon™ 407C and Freon™ 410A are as follows: HFC-32 HFC-125 HFC-134a Freon™ 407C (R-407C), wt% 23 25 52 Freon™ 410A (R-410A), wt% 50 50 — Because Freon™ 407C and Freon™ 410A are mixtures of HFCs, they have zero ODP. Table 1 lists the chemical names and formulae of the Comparing R404A and R410A with a Short Explanation of Both. R404A and R410A are two refrigerants that are commonly used in AC units. The differences between these two refrigerants come down to the pressure level, their chemical composition, and their efficiency. R404A is a hydrocarbon refrigerant that has a high pressure level of …equipment or components on R-410A equipment. Ensure service equipment is rated for R-410A.! WARNING Refrigeration systems contain refrigerant under pressure. Extreme caution should be observed when handling refrigerants. Wear safety glasses and gloves to prevent personal injury. During normal system operations, some components are hot and can ...Forane 410A Pressure Temperature Chart Forane 410A, R-410A, Pressure Temperature Chart, PT Chart, HVAC, refrigeration, air conditioning, refrigerant gassystem charge chart - refrigerant 410a pressure at suction service port (psig) connect pressure gauges to suction and liquid ports on unit. measure air temperature to outdoor coil. place an "x" on the appropriate chart where the suction and liquid pressures cross. if "x" is below ambient temperature line, add charge and repeat step 3.The liquid line pressure at 108°F saturation temperature is 356.5 PSIG. This screenshot of the Ref Tools app shows the liquid line pressure of R410A at saturation at 108°F. Notice how the slider has been set to BUBBLE point (inside the orange box). Vapor Line Pressure: Again, we already have the return air temp data, which is 74°F.What are normal pressures for R410A? 00:00 - What are normal pressures for R410A? 00:37 - Can you pump down a 410A system? 01:04 - What should my …OPERATING PRESSURE POINTS "Systems using R-410A operate at higher pressures [than R-22]," points out the Field Diagnostics team. "For example, to produce an evaporating temperature of 40 degrees F and a condensing temperature of 115 degrees, the suction and head pressures would be 83 psia and 257 psia in an R-22 system, while they would be 133 and 406 psia, respectively, in an R-410A ...Mini split manufacturers have been saying that since befrore R410A came out. All the old R22 units told you to weigh in charge only. And nobody is going to do that. It's like an quick change oil place telling customers that their engines have to be pulled and weighed to check their oil levels. No, its not the same.Currently working on a Bremar ice maker. Just did a compressor change and thought I weigh charged it perfectly. But it's not making good ice. I have only a suction port to read the pressures, and I'm getting 300kpa at the beginning of the 8.5 min cycle, and around 240kpa by the end. It runs for 8.5miutes then goes on defrost to drop the ice made.What is the normal suction pressure and discharge pressure of or freon R22 compressor. With 90 F outdoor temperature and 79 F indoor temperature you can expect a 120 F condensing temperature, (ambient plus 30). 90 F + 30 F = 120 F ; Convert temperature to pressure, R 22 at 120 F = 260 psi ; Indoor temperature (70 F) minus 40 F …Items Displayed in Black shows pressure in pounds per inch gauge. Data points are reproduced based on available information. Advantage assumes no responsibililty or liabilitly for data errors. For more information on refrigerant temperatures and pressures call the Advantage Service Department at 317-887-0729. Download the PDF document. Refrigerant Pressure Temperature Chart - PT Chart for R-410A, R-134A, and R-22. These are currently the three most widely used refrigerants on the market today for HVAC applications in residential and commercial use. R-22 refrigerant is the king and used widely in the residential and commercial markets followed by R-134A which is used in ...Jun 7, 2014 · Mini split manufacturers have been saying that since befrore R410A came out. All the old R22 units told you to weigh in charge only. And nobody is going to do that. It's like an quick change oil place telling customers that their engines have to be pulled and weighed to check their oil levels. No, its not the same. Jan 14, 2020 · R22 gauge pressure is 10.9 bar or 158.2 psi. High side pressure typically varies by equipment and metering controls. Low pressure or suction side typically varies by equipment. Low-pressure refrigerant turns on the carrier HVACR at 50 psi (R22 pressure at 30 degrees) and closes at 100 psi (R22 pressure at 85 degrees). We would like to show you a description here but the site won’t allow us.Check Pages 1-2 of normal refrigerant pressures for 404a ice machine in the flip PDF version. normal refrigerant pressures for 404a ice machine was published by Inez Powers on 2018-06-20. ... R-410A is potentially the most efficient refrigerant atmedium-temperature conditions (0 to 30 degrees F).equipment or components on R-410A equipment. Ensure service equipment is rated for R-410A.! WARNING Refrigeration systems contain refrigerant under pressure. Extreme caution should be observed when handling refrigerants. Wear safety glasses and gloves to prevent personal injury. During normal system operations, some components are hot …The manual states that the design pressure should be 255/465 psi. The running pressure is about 200 on the fluid line and 150 on the exhaust line. This is what my installer feels like a good pressure. However, the company that sold me the system said that the pressure should be ~100psi on either line.. r410a high/low pressures. Residential 410a system as ™ 410A Refrigerant (R-410A) 0 0 20 40 60 80 Temperature ™ 410A Refrigerant (R-410A) Replacement for R-13B1: Properties and Operating Characteristics ... pressure than R-13B1; in some systems, this pressure may be significantly higher. Before retrofitting an existing piece of ... Heat of Vaporization at Normal Boiling Point kJ/kg Btu/lb 276.2 118.8 118.8 51.1 Flammability Limit in Air (1 atm) vol ...™ 410A Refrigerant (R-410A) Replacement for R-13B1: Properties and Operating Characteristics ... pressure than R-13B1; in some systems, this pressure may be significantly higher. Before retrofitting an existing piece of ... Heat of Vaporization at Normal Boiling Point kJ/kg Btu/lb 276.2 118.8 118.8 51.1 Flammability Limit in Air (1 atm) vol ... Heating mode: outside temp >65F: Run AUX only - lock out c The pressures were still at the 130 on suction side and 335 on the high side, but the cooling has gone away, suction side does not get cool. It has a metering orifice, no txv So, I thought I may be overcharged, since the liquid got in. I reclaimed some 410a (not measured) which sent the pressure too 150 on suction side and 365 on high side ...We can see that at 72°F, the R410A pressure is 208,4 psig. Example 2: What are 410A pressures on an 85 degree day? The operating pressure of 410A on an 85 degree day is 254.6 psig. Example 3: What are 410A pressures on a 70 degree day? The operating pressure of 410A on a 70 degree day is 201.5 psig. Example 4: What are 410A pressures on a 65 ... Turn the thermostat to cool and set the target tempe...

Continue Reading